<LOGO>
FM Transmitter Measurement Report
Created: 2023-11-05 19-29-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.40 MHz 3/5, 40 dBuV VIBRA fm
Pilot RDS Phase Difference
6.7 kHz 3.5 kHz 40 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 72 kHz 1797 0,6121
Modulation Power
Limit Measuring Tolerance
9,0 dBr 1,0 dBr
MIN AVE MAX % above 10,0 dBr
6,2 dBr 7,58 dBr 8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VIBRA fm" F560 9 (Varied) 1 0 1 1 --:--
RT
"VIBRATION - Vibrez avec nous "
AF EON
90.3, 93.4, 101.7, 102.0, 102.1 MHz -
FM Scope Station: 93.40 MHz, signal: 3/5 (40 dBuV) Max at: 72 kHz MIN: 13 kHz % above 75 kHz: 0,6121 Acquired: 2023/11/05 19:28:23 Total samples: 1797 Equivalent time: 0:01:29 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150